Paradyne IP DSLAM BitStorm 2600 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Sítě Paradyne IP DSLAM BitStorm 2600. Paradyne IP DSLAM BitStorm 2600 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - IP DSLAM

BitStorm® 2600IP DSLAMInstallation GuideDocument No. 2600-A2-GN20-40March 2005

Strany 2

About This Guideiv March 2005 2600-A2-GN20-40Related Product DocumentsDocumentation for the BitStorm 2600 IP DSLAM is available on the World Wide Web

Strany 3

2600-A2-GN20-40 March 2005 1-11InstallationOverviewThe BitStorm® 2600 is a family of stackable IP DSLAMs designed for installation in a Central Office

Strany 4 - C March 2005 2600-A2-GN20-40

1. Installation1-2 March 2005 2600-A2-GN20-40Up to eight BitStorm 2600 units can be logically stacked, with aggregation for up to 192 ports of DSL t

Strany 5

1. Installation2600-A2-GN20-40 March 20051-3Cables RequiredTable 1-1 shows all the cables that may be required for your installation.Table 1-1. Cable

Strany 6 - E March 2005 2600-A2-GN20-40

1. Installation1-4 March 2005 2600-A2-GN20-40Unpacking the HardwareHANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES This product is designed to pro

Strany 7 - Contents

1. Installation2600-A2-GN20-40 March 20051-5Table 1-2. Contents of Hardware Kit Shipped with the BitStorm 2600Appearance Description QuantityFlat-head

Strany 8

1. Installation1-6 March 2005 2600-A2-GN20-40Mounting Configurations Three basic installation configurations are available: Rack mount – see Instal

Strany 9 - About This Guide

1. Installation2600-A2-GN20-40 March 20051-73. Identify six flat-head screws (for 19-inch racks) or six machine screws (for 23-inch racks) provided wi

Strany 10 - Related Product Documents

1. Installation1-8 March 2005 2600-A2-GN20-40Installing the BitStorm 2600 Into a RackTwo types of mounting screws are provided. Use: #10-32 mountin

Strany 11 - Installation

1. Installation2600-A2-GN20-40 March 20051-93. Insert and tighten the screws in the top screw positions, then tighten the bottom screws. 03-17436PORT1

Strany 12 - Preparation

A March 2005 2600-A2-GN20-40Copyright 2005 Paradyne Corporation.All rights reserved.Printed in U.S.A.NoticeThis publication is protected by federal co

Strany 13 - Cables Required

1. Installation1-10 March 2005 2600-A2-GN20-40Installing the BitStorm 2600 on a WallWall mounting requires two wood screws suitable for the weight o

Strany 14 - Package Contents

1. Installation2600-A2-GN20-40 March 20051-116. Install two wood screws (not provided) at the same height above the floor and 18.75 inches (476.25 mm)

Strany 15 - 02-17325

1. Installation1-12 March 2005 2600-A2-GN20-40Installing the BitStorm 2600 on a Shelf or DesktopIf the BitStorm 2600 will be placed on a shelf or de

Strany 16 - Mounting Brackets

2600-A2-GN20-40 March 2005 2-12CablingCabling OverviewThe BitStorm 2600 has a large variety of possible cabling configurations. This chapter describes

Strany 17 - 2600-A2-GN20-40 March 2005

2. Cabling2-2 March 2005 2600-A2-GN20-40DSL PortsThe BitStorm 2600 DSL connector supports the tip and ring connections of up to 24 DSL ports over a

Strany 18 - Procedure

2. Cabling2600-A2-GN20-40 March 20052-34. Tighten the cable tie around the connector and trim the excess.5. If you use an internal POTS splitter, repe

Strany 19

2. Cabling2-4 March 2005 2600-A2-GN20-402. Connect the other end of the uplink cable to the uplink interface, such as an Ethernet switch.3. Port 3 (

Strany 20

2. Cabling2600-A2-GN20-40 March 20052-5T1 or E1 UplinkModels that support T1 or E1 have eight ports that can be used in any combination to provide PPP

Strany 21 - 17.85 in (453 mm)

2. Cabling2-6 March 2005 2600-A2-GN20-40Chaining BitStorm 2600sUp to eight BitStorm 2600s can be chained together to use a single uplink. The same p

Strany 22

2. Cabling2600-A2-GN20-40 March 20052-7Management PortPort 1 can be used to connect the BitStorm 2600 to a network management system using a 10BaseT o

Strany 23 - Cabling Overview

2600-A2-GN20-40 March 2005 BSoftware and Firmware License AgreementThe terms and conditions of this License Agreement (the “Agreement”) will apply to

Strany 24 - DSL Ports

2. Cabling2-8 March 2005 2600-A2-GN20-40Console PortThe CONSOLE port normally serves as the primary user interface with the BitStorm 2600 during ins

Strany 25 - GigE Uplink (Port 3)

2. Cabling2600-A2-GN20-40 March 20052-9Connecting a Modem to the Console PortProcedureTo connect a modem to the CONSOLE port:1. Determine and procure

Strany 26 - 10/100BaseT Uplink (Port 2)

2. Cabling2-10 March 2005 2600-A2-GN20-40Alarm InterfaceThe ALARM interface consists of five contacts. Three of the contacts provide access to alarm

Strany 27 - T1 or E1 Uplink

2. Cabling2600-A2-GN20-40 March 20052-11GroundProcedureTo connect the unit to a ground:1. Crimp a ring terminal onto the stripped end of 14 AWG or hea

Strany 28 - Chaining BitStorm 2600s

2. Cabling2-12 March 2005 2600-A2-GN20-40Connecting to PowerThe BitStorm 2600 can be powered by any AC power source supplying 90–265 VAC at 47–63 Hz

Strany 29 - Management Port

2600-A2-GN20-40 March 2005 3-13LEDsLED LocationsThe locations of the System and DSL Port LEDs on the front panel of the BitStorm 2600 are shown in Fig

Strany 30 - Console Port

3. LEDs3-2 March 2005 2600-A2-GN20-40LED MeaningsWhen power is first applied to the unit, it performs a power-on self-test. When this test is succes

Strany 31 - Serial Port

2600-A2-GN20-40 March 2005 4-14ConfigurationOverviewThe BitStorm 2600 is designed to require minimal configuration before it can be accessed by a Netw

Strany 32 - Alarm Interface

4. Configuration4-2 March 2005 2600-A2-GN20-40Using the CLI A command line interface (CLI) can be used to configure and monitor the unit. The CLI is

Strany 33 - To Earth Ground

4. Configuration2600-A2-GN20-40 March 20054-3Configure Management Inband AddressThe configure management inband address command specifies the IP addre

Strany 34 - Connecting to Power

C March 2005 2600-A2-GN20-40 Important Safety Instructions1. Read and follow all warning notices and instructions marked on the product or included in

Strany 35 - LED Locations

4. Configuration4-4 March 2005 2600-A2-GN20-40BitStorm 2600 Startup ProcedureYou can initialize your BitStorm 2600 via a PC or terminal connected to

Strany 36 - LED Meanings

4. Configuration2600-A2-GN20-40 March 20054-5Startup Procedure for Inband ManagementWith inband management, the BitStorm 2600 is managed using the upl

Strany 37 - Configuration

4. Configuration4-6 March 2005 2600-A2-GN20-40Using the Web InterfaceTo access the web interface:Procedure1. Open your web browser. (Internet Explor

Strany 38 - Using the CLI

4. Configuration2600-A2-GN20-40 March 20054-7System / UsersFor security reasons, it is a good idea to change the default password the first time you u

Strany 39

4. Configuration4-8 March 2005 2600-A2-GN20-40Configuration / Management / SNMPSNMP access to the unit is disabled by default. The read-only communi

Strany 40 - Management Modes

2600-A2-GN20-40 March 2005 A-1AConnectors and Pin AssignmentsOverviewThe following sections provide pin assignments for: DSL Ports and POTS Splitter

Strany 41

A. Connectors and Pin AssignmentsA-2 March 2005 2600-A2-GN20-40DSL Ports and POTS Splitter ConnectorsThe 50-pin RJ21X Telco connector labeled DSL Po

Strany 42 - Using the Web Interface

A. Connectors and Pin Assignments2600-A2-GN20-40 March 2005A-3Port 1 and Port 2 10/100BaseT ConnectorsPort 1 and Port 2 are 8-pin unkeyed modular jack

Strany 43 - System / Users

A. Connectors and Pin AssignmentsA-4 March 2005 2600-A2-GN20-40Port 3 GigE SFP ConnectorPort 3’s GigE interface is a standard SFP socket. Table A

Strany 44

A. Connectors and Pin Assignments2600-A2-GN20-40 March 2005A-5E1 and T1 Uplink Connectors The E1 and T1 connectors on T1/E1 MLPPP models are single,

Strany 45 - Overview

2600-A2-GN20-40 March 2005 D13. The power supply cord for countries other than North America is to be a minimum H05 V V-F type, min. 0.75 mm2, 2-condu

Strany 46 - 02-17151

A. Connectors and Pin AssignmentsA-6 March 2005 2600-A2-GN20-40ALARM ConnectorThe alarm relay reports major alarms through the ALARM connector. The

Strany 47 - Port 3 1000BaseT Connector

2600-A2-GN20-40 March 2005 B-1BEquipment ListAll BitStorm 2600 models include the BitStorm 2600, 19- and 23-inch mounting brackets and hardware, and a

Strany 48 - Port 3 GigE SFP Connector

B. Equipment ListB-2 March 2005 2600-A2-GN20-40 2674-A1-422 24 SHDSL None North America E1 MLPPP (8 ports)Table B-2. BitStorm 2600 Related Equipment

Strany 49 - Console Port Connector

2600-A2-GN20-40 March 2005 C-1CTechnical SpecificationsTechnical specifications are subject to change without notice. Table C-1. BitStorm 2600 Technic

Strany 50 - 5 4 3 2 1

C. Technical SpecificationsC-2 March 2005 2600-A2-GN20-40Interfaces  DSL PORTS: 50-pin RJ21X Telco-type connector POTS: 50-pin RJ21X Telco-type co

Strany 51 - Equipment List

2600-A2-GN20-40 March 2005 IN-1IndexNumerics10/100BaseT pinouts, A-31000BaseT pinouts, A-3AAC power, 2-12Activity LEDs, 3-2administrator, login,

Strany 52

IndexIN-2 March 2005 2600-A2-GN20-40EE1 uplinkcabling, 2-5pin assignments, A-5earth ground, 2-11Electromagnetic Compatibility (EMC), C-1EMS, 4-4E

Strany 53 - Technical Specifications

Index2600-A2-GN20-40 March 2005IN-3pin assgnmentsE1, A-5pin assignments, A-1Alarm, A-6CONSOLE port, A-3Console port, A-5Management port, A-3Port

Strany 54 - Specifications Criteria

IndexIN-4 March 2005 2600-A2-GN20-40

Strany 55 - Numerics

E March 2005 2600-A2-GN20-40JapanClass A ITEThis is a Class A product based on the standard of the Voluntary Control Council for interference by Infor

Strany 56

2600-A2-GN20-40 March 2005 iContents Software and Firmware License Agreement . . . . . . . . . . . . . . . . . . . . BAbout This Guide Document Pu

Strany 57

Contentsii March 2005 2600-A2-GN20-40 Connecting to Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-123LEDs LED

Strany 58 - March 2005 2600-A2-GN20-40

2600-A2-GN20-40 March 2005 iiiAbout This GuideDocument Purpose and Intended AudienceThis document is written for technicians who install the BitStorm®

Komentáře k této Příručce

Žádné komentáře